Home / Sensors / SN-3002-TR-ECTHNPKPH-N01

SN · RS-485 sensor

Puruisenshe (普锐森社)

SN-3002-TR-ECTHNPKPH-N01

7-register probe with write-in N-P-K (ZTS-3002-class behaviour).

✓ Verified for SankhyaMoistureTemperatureECpHN-P-KSalinityTDSVerification 0.80 · verified
At a glance

The SN-3002-TR-ECTHNPKPH-N01 is a 7-in-1 RS-485 soil probe reporting moisture, temperature, EC, pH, N-P-K, salinity and TDS over Modbus-RTU on RS-485 at 4800 bps, 8N1, on DC 4.5–30 V. This guide documents 27 registers, default Modbus address 1. It is register-compatible with the ZTS-3001-TR-ECTHNPKPH-N01, which the same firmware profile reads unchanged. Sankhya firmware profile: ZTS_7in1.

Broad telemetry without hiding the verification boundary

Sankhya Farms has a profile for the SN-3002-TR-ECTHNPKPH-N01 register family and can place its reported moisture, temperature, EC, pH, nutrient, salinity and TDS fields in the free cloud dashboard. The wide register map is useful because one RS-485 address can supply a compact monitoring record, but this model carries a lower verification score than the fully confirmed ZTS-3001 map. N-P-K behaviour should be checked against the exact manual and a known sample before those fields are treated as live agronomic measurements.

For moisture, temperature, EC and pH observation, the same dashboard can serve an orchard, greenhouse, container trial, home garden or media-grown crop. It can also act as a logging surface during bench testing: power the sensor, inspect each returned word, and compare the decoded value with a reference instrument. This is often more useful than a one-off serial-terminal printout because changes and intermittent faults remain visible. For hydroponic reservoirs or water treatment, choose liquid-rated probes even when the desired pH or EC parameter has the same name.

Use with care: Sankhya can transport and label every documented field, but software compatibility is not a substitute for confirming what the physical sensing element actually measures. Compare the fully documented ZTS-3001 7-in-1.

How do I look up a field in the SN-3002 response?

The primary family begins at 0000H: moisture, signed temperature, EC and pH occupy the first four defined addresses; N, P and K are listed at 0004H0006H; salinity and TDS are 0007H and 0008H. The remaining documented words include conversion, calibration and configuration values and should not be displayed as live measurements. Sankhya maps by address and meaning, not by simply charting every returned integer.

Why is this page cautious about N-P-K?
Closely named ZTS and SN variants use different nutrient behaviours, including writable temporary fields and genuine read-only probe values. Confirming the exact revision avoids presenting a stored number as a new sensor reading.
Can the other fields still be useful?
Yes. Moisture, temperature, EC and pH histories remain useful for observation and comparison when the corresponding register map and calibration have been verified.

Bus & electrical specs

Note. As with the ZTS-3002, the NPK fields are write-in temporaries, not live readings.
Protocol
Modbus-RTU over RS-485
Default baud
4800 bps
Serial format
8N1
Function codes
0x03, 0x06
Supply voltage
DC 4.5–30 V
Power
≤ 0.5 W (24 V DC)
Default address
1
Ingress / housing
IP68
Probe / element
Stainless steel
Operating temp.
−40 to +80 °C (probe)
Firmware profile
ZTS_7in1

Specs sourced from: Official SN-3001-TR-*-N01 datasheet (R224096); ZTS-compatible register layout.

Modbus-RTU register map

Function codes 0x03, 0x06 at 4800 bps, 8N1. Data registers are read with 0x03; configuration registers are written with 0x06. PLC column shows the 4xxxx Modbus holding-register convention.

Inherited map. SN-3002-TR-ECTHNPKPH-N01 is register-compatible with the ZTS-3001-TR-ECTHNPKPH-N01 and shares its layout. The table below is that confirmed map. SN-3002 is the 7-parameter variant of SN-3001. Given SN-3001 is confirmed identical to ZTS family, SN-3002 almost certainly maps to ZTS_7in1 profile. Verify NPK caveat applies.
RegisterPLCParameterTypeScaleUnitR/WNotes
0000H40001Soil moistureuint160.1%RO
0001H40002Soil temperatureint160.1°CRONegative values in two's complement.
0002H40003Electrical conductivityuint161uS/cmRO
0003H40004pHuint160.1pHRO
0004H40005Nitrogen (actual value)uint161mg/kgROLIVE probe reading per ZTS-3001 official PDF. Range 1-1999 mg/kg. Accuracy ±2%FS. Different from ZTS-3002 where this is a writable temporary value.
0005H40006Phosphorus (actual value)uint161mg/kgROLIVE probe reading per ZTS-3001 official PDF. Different from ZTS-3002.
0006H40007Potassium (actual value)uint161mg/kgROLIVE probe reading per ZTS-3001 official PDF. Different from ZTS-3002.
0007H40008Salinityuint161mg/LROReference value only.
0008H40009TDSuint161mg/LROReference value only.
0022H40035Conductivity temperature coefficientuint160.1%RW0-100 corresponds to 0.0%-10.0%. Default 0.
0023H40036Salinity conversion coefficientuint160.01RWDefault 55 (0.55).
0024H40037TDS conversion coefficientuint160.01RWDefault 50 (0.50).
0050H40081Temperature calibration valueint160.1°CRW
0051H40082Moisture calibration valueint160.1%RW
0052H40083Conductivity calibration valueint161uS/cmRW
0053H40084pH calibration valueint160.1pHRW
04E8H41001Nitrogen coefficient high worduint16RWIEEE 754 float high 16 bits.
04E9H41002Nitrogen coefficient low worduint16RWIEEE 754 float low 16 bits.
04EAH41003Nitrogen deviationint161RW
04F2H41011Phosphorus coefficient high worduint16RWIEEE 754 float high 16 bits.
04F3H41012Phosphorus coefficient low worduint16RWIEEE 754 float low 16 bits.
04F4H41013Phosphorus deviationint161RW
04FCH41021Potassium coefficient high worduint16RWIEEE 754 float high 16 bits.
04FDH41022Potassium coefficient low worduint16RWIEEE 754 float low 16 bits.
04FEH41023Potassium deviationint161RW
07D0H42001Device addressuint161RWRange 1-254. Factory default 1.
07D1H42002Baud rateuint161RWFactory default 1 (4800 bps). 0=2400; 1=4800; 2=9600

Worked query

# Read moisture+temp+EC+pH (4 registers from 0x0000) request 01 03 00 00 00 04 44 09 response 01 03 08 02 92 FF 9B 03 E8 00 38 57 B6 # moisture=65.8%, temperature=-10.1°C, EC=1000 uS/cm, pH=5.6

Changing address & baud rate

This probe is configured over the same RS-485 bus using Modbus write commands (function code 0x06). Configure one device at a time on the bus.

Notes & caveats

SN-3002 is the 7-parameter variant of SN-3001. Given SN-3001 is confirmed identical to ZTS family, SN-3002 almost certainly maps to ZTS_7in1 profile. Verify NPK caveat applies.

Common questions

What baud rate does the SN-3002-TR-ECTHNPKPH-N01 use by default?
4800 bps, 8N1. It is a Modbus-RTU slave; default address 1.
What supply voltage does the SN-3002-TR-ECTHNPKPH-N01 need?
DC 4.5–30 V (≤ 0.5 W (24 V DC)).
How do I change the SN-3002-TR-ECTHNPKPH-N01 Modbus address?
Write the device-address register with function code 0x06, one device on the bus at a time, then power-cycle. See the Configuration section above.
Is the SN-3002-TR-ECTHNPKPH-N01 compatible with the Sankhya platform?
Yes — it is in the Sankhya RS-485 sensor library and the firmware-generation pipeline can produce node firmware for it.
Is the SN-3002-TR-ECTHNPKPH-N01 the same as the ZTS-3001-TR-ECTHNPKPH-N01?
They are register-compatible, not identical products. Both expose the same parameter set and the same Modbus register map, and Sankhya reads both with the ZTS_7in1 firmware profile. The ZTS-3001-TR-ECTHNPKPH-N01 is specified at DC 5–30 V against DC 4.5–30 V here. Housing, cable gland and probe material can differ between vendors, so check the electrical specs above before substituting one for the other.

How this differs from similar models

How the SN-3002-TR-ECTHNPKPH-N01 compares with the other RS-485 models in the Sankhya library. "Drop-in" means the same parameter set and the same register map, read by the same firmware profile.

ModelRelationshipMeasuresBaudDifference
ZTS-3001-TR-ECTHNPKPH-N01Drop-inMoisture, Temperature, EC, pH, N-P-K, Salinity, TDS4800Same parameter set and register map. Differs in supply range (DC 5–30 V).
SN-3001-TR-ECTHPH-N01SiblingMoisture, Temperature, EC, pH, Salinity, TDS4800Drops N-P-K.

Related SN sensors

Run this sensor on a Sankhya node

Every sensor on this page is in our RS-485 library. Pick your model, and the firmware-generation pipeline builds the Modbus (or ASCII) polling code for an ESP32-S3 node — no hand-coding the register math.